DFL处理希捷硬盘ST2000LM007 SP Regen FAIL Update Mask错误数据恢复步骤
这个希捷故障硬盘是数据恢复工程师团队进行远程数据恢复案例,现已完全取得数据,用户是一个印度DFL数据恢复设备用户。
当用户将故障硬盘连接到DFL-SRP Seagate希捷固件维修工具,打开硬盘,出现“SP Regen FAIL,Update Mask”错误,无法进入F3 T>。错误消息如下:
Boot 0x80M
Rst 0x80M
Srv DETCR init 0x0000
(P) SATA Reset
RAW OFF
PASS
(DOS Table) Worst Count: 00000EC2 At SU: 0015EE5D NT: 00000000 OT: 00000001
(POR) Recover Secondary MCMT Opened Recovered
(MC POR Duration): 0000000166
Intel 6G->3G
Send Status: COMRESET seen
CSpd= 3Gbps
DSC
Update Mask – 000000002B24DFF0 – 00000008 – 00
Update Mask – 000000002B24DFF8 – 00000008 – 00
Update Mask – 000000002B24E000 – 00000008 – 00
Update Mask – 000000002B24E008 – 00000008 – 00
Update Mask – 000000002B24E010 – 00000008 – 00
Update Mask – 000000002B24E098 – 00000008 – 00
Update Mask – 000000002B24E0A0 – 00000008 – 00
Starting LBA of RW Request=000564855A Length=00001DB0
ProcessRWError -Read- at LBA 0005649C39 Sense Code=43110081
Out: [PRA]!
Update Mask – 000000002B24E2F0 – 00000008 – 00
Update Mask – 000000002B24E2F8 – 00000008 – 00
Update Mask – 000000002B24E300 – 00000008 – 00
Update Mask – 000000002B24E308 – 00000008 – 00
Common path start quit now
ProcessRC: 00000000,00000000
ReadContinuous: 05649C63,00000233
TotalEntries:0000 XfrLen:0233
UnrecovSectorCount:0000,0000
NumUDEs: 00000000,00000000
Failed: 40000087
Out:
SP Regen FAIL
SPRegen [0000|03110488] @LBA=0x05649C64
Setup currentretry count
Hd 3 Err Blk 5649C64 BER pre -1.827226
Out:
Update Mask – 000000002B24E320 – 00000008 – 00
Harden – 05649C64
InitiateMarkPendingReallocateRequest for disc_lba: 0005649C64 CHS: 00013215.03.00C6
Assert 741D – LBA 05649C64!
Starting LBA of RW Request=000564855A Length=00001DB0
ProcessRWError -Read- at LBA 0005649C65 Sense Code=43110081
Common path start quit now
ProcessRC: 00000002,00000000
ReadContinuous: 05649C65,00000231
TotalEntries:000D XfrLen:0231
UnrecovSectorCount:000D,000C
NumUDEs: 0000000D,0000000C
Failed: 40000087
Out:
为了修复这个故障硬盘,首先,工程师与用户连线沟通后确定了进入F3 T>的正确时间,备份了原始的ROM;
其次,生成了解锁ROM,写入解锁ROM,复位电源后发送解锁key,进入F3 T>,备份了NGlist,清除了glist;
最后,重建编译器,使用ATA初始化ID。
用户可以观看以下视频案例研究:
百度云链接: https://pan.baidu.com/s/1BWgso8cDHTu-pnz944UdTg 提取码: t48a 
在固件问题修复后,工程师打开DFL-DDP数据恢复程序以镜像恢复丢失的数据。